l Water, sewage ( with low particle content ) and seawater;
l Water supply and drainage water;
l Power plants ( nuclear power plant, thermal and hydropower plants ), heat energy, boiler feed water and energy management system;
l Metallurgy and mining applications ( cooling water and acid recovery, for example );
l Petroleum and chemicals;
l Food, beverage and pharmaceutical;
l Marine operation and maintenance;
l Energy economy supervision and water conservation management;
l Pulp and paper;
l Pipeline leak detection;
l Regular inspection, tracking and collection;
l Energy measuring and balance;
Network monitoring systems and energy / flow computer management.
The installation of this ultrasonic flow meter is the simplest one of all kinds of flow meters. Only one suitable measuring site needed, plug the transducers on the pipe and then start the measurement.
When selecting a measurement site, it is important to select an area where the fluid flow profile is fully developed to guarantee a highly accurate measurement. Use the following guidelines to select a proper installation site:
l Choose a section of pipe that is always full of liquid, such as a vertical pipe with flow in the upward direction or a full horizontal pipe.
l Ensure enough straight pipe length at least equal to the figure shown below for the upstream and downstream transducers installation. Try to avoid Ensure enough straight pipe length at least equal to the figure shown below for the upstream and downstream transducers installation.
l On the horizontal pipe, the transducer should be mounted on the 9 and 3 of the pipe, avoiding the position of 6 and 12, in case of the signal attenuation caused by pipe at the bottom sediment or bubble、cavitation on the pipe.
l Ensure that the measuring site temperature is under the transducer temperature limits.
l Consider the inside condition of the pipe carefully. If possible, select a section of pipe where the inside is free of excessive corrosion or scaling.
l Choose a section of sound conducting pipe.